dBµV ↔ V Voltage Conversion Table (with 50 Ω dBm)

Reference table of µV, mV, V and the equivalent 50 Ω dBm value from 0 to 140 dBµV.

EMI receiver readings and conducted emission limits are written in dBµV, while spectrum analyzers often display dBm. In a 50 Ω system dBµV = dBm + 107, so the two move directly into each other. That value is the last column of the table.

Voltage conversion table (10 dB steps; dBm at 50 Ω)

dBµVµVmVVdBm (50 Ω)
010.0011×10⁻⁶-107
103.1620.0031623.16×10⁻⁶-97
20100.011×10⁻⁵-87
3031.620.031623.16×10⁻⁵-77
401000.11×10⁻⁴-67
50316.20.31623.16×10⁻⁴-57
60100010.001-47
7031623.1620.003162-37
8010000100.01-27
903162031.620.03162-17
1001000001000.1-7
110316200316.20.31623
1201×10⁶1000113
1303.16×10⁶31623.16223
1401×10⁷100001033

Open the calculator → dBµV ↔ Volt Converter

Formula

V(µV) = 10^(V(dBµV) / 20)
V(dBµV) = 20·log₁₀(V(µV))

Worth memorizing

  • 120 dBµV = 1 V
  • 60 dBµV = 1 mV
  • At 50 Ω, dBµV = dBm + 107
  • 107 = 90 + 10·log₁₀(50)

Common mistakes

  • Using +107 regardless of impedance. It is specific to 50 Ω; at 75 Ω it is +108.75.
  • Using 10·log₁₀ for voltage. Voltage is an amplitude quantity, so it uses 20·log₁₀.
  • Treating the quasi-peak and peak readings as the same. For broadband noise the difference is large.
  • Forgetting the LISN division factor and insertion loss. Add the values from the calibration certificate to get the actual terminal voltage.

Related calculators

All conversion tables

Results and summaries are for reference. For certification and test reports use the latest official standard text and calibrated instrument data. Last updated: 2026-10-10