Self Pre-Compliance Checklist Before an Emission Test
A checklist covering EUT configuration, instrument settings, environment, measurement procedure and records before a formal emission test.
Booking a formal test lab costs money and schedule. A quick in-house pre-check with modest equipment greatly reduces the risk of a retest. Use this checklist to see that nothing is missed.
EUT configuration
- Confirm the same firmware, enclosure, cables and grounding as the final product.
- Connect real cables to every port and match representative cable lengths to the standard’s setup.
- Define the worst-case operating mode (highest clock, maximum load, all interfaces active) and write it in the test plan.
Instruments and settings
- Receiver settings: RBW 120 kHz for 30 MHz–1 GHz, peak detector for pre-scans, quasi-peak and average for final measurements.
- Use the latest calibration values for antenna factor, cable loss and preamp gain. (Calculators: cable-loss scaling, level budget)
- Confirm the receiver noise floor is at least 6 dB below the limit. (Calculator: noise floor)
- With stepped scans, check the step is at most half the RBW and that total time fits the schedule. (Calculator: stepped scan time)
Environment
- Save an ambient scan with the EUT off first. Knowing where broadcast and communication signals sit makes later interpretation easier.
- Check the measurement and antenna-to-EUT distance with a tape and photograph it.
- Keep the reflecting floor, nearby metal objects and cable layout constant.
Measurement procedure
- Pre-scan with the peak detector in both vertical and horizontal polarisation.
- Pick frequencies within 6 dB of the limit, maximise by antenna height and turntable angle, and measure finally with quasi-peak.
- For conducted emissions check both QP and average on each of the L and N lines.
Records and judgement
- Keep photos of the setup, cable layout, equipment list and settings, plus date and temperature/humidity.
- Tabulate the margin (limit − measured) per frequency and flag items under 3 dB as countermeasure candidates. (Calculator: limit margin)
- Agree beforehand how uncertainty is handled (direct comparison or guard band).
Pre-compliance results are a preliminary risk assessment, not an official report. In-house equipment can differ by several dB from a formal test because of its accuracy limits, so secure enough margin.